2 July 2026 · 5 min read · NZ Flow Group
Every mag meter spec sheet used to carry the same fine print: 5 diameters of straight pipe upstream, 2 to 3 downstream, no exceptions. On a real site, next to a manifold, an elbow, or a pump outlet, that straight run often simply isn't there. Zero:zero (0:0) mag meters were built to solve exactly that problem, and the three major brands we supply have each arrived at a genuinely different way of doing it.
The straight-run rule exists because a standard electromagnetic flow meter needs a settled, axially symmetric flow profile passing through its electrodes to measure accurately. An elbow, tee, valve, or pump immediately upstream introduces swirl and turbulence, and a meter reading that disturbed flow will drift outside its accuracy spec. The traditional fix was simple: give the water enough straight pipe to settle down before it reaches the meter. The problem is that a lot of real installation sites, particularly retrofits, don't have that pipe run to give.
A zero:zero rating means a meter can be installed with no required straight run on either side, directly behind a bend, valve, or reducer, without a documented accuracy penalty. It's a genuinely useful capability for site-constrained municipal and industrial installs across Canterbury. But "zero:zero" isn't one piece of technology licensed across the industry, it's a design goal that Krohne, Endress+Hauser, and ABB have each solved with different engineering.
Krohne's WATERFLUX range uses a rectangular, reduced cross-section measuring tube rather than the round full-bore tube found on a standard mag meter. That shape change does the work mechanically: it conditions the flow profile as water passes through, so the meter doesn't need a long straight run beforehand to get a settled reading. WATERFLUX meters are rated for installation directly behind elbows, valves, or reducers, and their sealed, no-moving-parts construction also makes them suitable for direct burial or flooded chamber installations, relevant for meter pits and underground point-of-take setups common on Canterbury properties.
Endress+Hauser's approach with the Promag W range (available with the "0 x DN full bore" option) keeps the standard round, full-bore tube, so there's no pressure loss or flow restriction, and instead solves the problem with the electronics. Multiple measuring electrodes generate a far denser set of flow data than the standard two-electrode design, and Endress+Hauser's signal processing uses that data to filter out swirl computationally. The result is a meter that holds its rated accuracy directly downstream of bends, tees, or other obstructions, without narrowing the pipe to force the flow to settle.
ABB's zero:zero offering isn't new. The WaterMaster FER, with its reduced bore sensor design, has been ABB's 0xD/0xD meter for years, giving accurate readings with no required straight run upstream or downstream. In June 2026, ABB extended that same reduced bore approach to its ProcessMaster FER620, adding a fully welded, hermetically sealed sensor construction rated IP68 for direct burial without a protective chamber. ABB has positioned the update specifically for pumping stations, water abstraction, and treatment facilities, sites where straight-run space is hardest to find.
For our customers, the practical upshot is choice. A site with an existing manifold right at the point of take, a pump station with no room to re-pipe, or a district metering point squeezed between two fittings no longer has to force a straight-run compromise or pay for costly pipe rerouting to get a compliant, accurate meter installed. Because we're not tied to a single brand, we can match the zero:zero solution to the actual constraints of your site rather than defaulting to whichever manufacturer we happen to stock.
Verification requirements don't change with a zero:zero install. Whichever brand ends up on site, the meter still goes on the standard 5-year verification cycle, and Blue Tick installation, verification, and data hosting work the same way it always has. What does change is the verification method: ECan's standard clamp-on ultrasonic verification needs a run of straight, accessible pipe to clamp the Flexim Fluxus F601 onto, which a zero:zero installation by definition doesn't have. Where a zero:zero mag meter is installed, we carry out an electronic verification instead, using brand-specific test equipment to check the meter against its original factory calibration. As with any compliance verification, this can only be used as an alternative to a clamp-on/flow-through verification where prior agreement is in place with the relevant regional council.
If you're planning a new install or a replacement on a site where a straight run is hard to come by, tell us about your constraints and we'll recommend the meter that actually fits, not just the one that's easiest to spec.
Tell us about your installation constraints and we'll recommend the best zero:zero option for your site, independent of brand.